Carbon Monoxide (CO) Detection Systems
From monitoring in enclosed spaces to control scenarios.
A carbon monoxide detection project requires sensor placement, monitoring of measurement data and the relevant control scenarios to be considered together. Narstek provides site surveys, design, installation, commissioning and maintenance for car parks and other enclosed areas.
Site and Infrastructure Survey
The layout, sections, use and existing ventilation of the enclosed area are assessed. Detector locations and monitoring zones are planned in line with the project requirements.
Detector and Panel Installation
CO detectors, the control panel, communication lines and power infrastructure are treated as a compatible system. Device selection and installation conditions are assessed in accordance with the manufacturer’s technical documentation.
Ventilation Integration
Interfaces between panel outputs and ventilation automation are planned. Warning and control responses are agreed with the relevant project teams, followed by commissioning checks.
Maintenance and Sensor Monitoring
Detector status, fault logs and communications are checked. Sensor life, functional testing, and any required calibration or replacement are addressed in line with the device requirements.
Carbon monoxide (CO) detection and fire suppression are different systems
This service covers the detection of carbon monoxide gas and the associated warning and control functions; it should not be confused with a gas fire suppression system. The number and locations of sensors, along with control thresholds, are determined by a site-specific design; one layout or setting is not suitable for every area.
Equipment used in this service

Apollo 58000-300APO Discovery Carbon Monoxide Detector

Detnov DMD-500 Standard Carbon Monoxide Detector

Finder GF 1224 CO Carbon Monoxide Gas Detector

Global Fire DMD500 Carbon Monoxide Gas Detection Detector

Honeywell Esser 805553 TF 2001 Carbon Monoxide (CO) Cell

Kilsen KMD300 Carbon Monoxide Gas Detector

Prosense PPS-CO Carbon Monoxide Gas Detector

Redban CO540 Addressable Carbon Monoxide Detector
About Carbon Monoxide (CO) Detection Systems
Can a Carbon Monoxide (CO) detection panel be connected to the ventilation system?
Integration can be planned where compatible outputs and automation interfaces are available. The connection method and control scenario are determined for each project.
Where should detectors be installed?
Locations are determined in view of the physical conditions of the area, air movement, project requirements and the device manufacturer’s instructions.
How can I tell when a sensor needs replacing?
Fault information, maintenance records, the service life specified by the manufacturer and technical checks are considered together.
Request a site survey and quote for your project
Tell us about your building, existing system and requirements; together, we can determine the right solution.