Aritech DP2061N Addressable Optical Smoke Detector
Request a quote for pricing and availability. Installation, commissioning and compatibility checks with your existing system are also available.
Product description
1. Product Name: Aritech DP2061N Addressable Optical Smoke Detector
2. Description:
What Is the Aritech DP2061N Addressable Optical Smoke Detector?
Aritech DP2061N is an addressable optical smoke detector with a field-replaceable optical chamber, operating with the 2000 Series protocol. Its low-profile design, dual alarm LEDs providing 360° visibility and standard remote indicator output comply with EN54-7.
Operating Principle
The detector operates using the optical light-scattering principle: smoke particles entering the chamber scatter light, and this change is detected by the receiver. The measured value is communicated to the panel using the 2000 Series protocol. Sensitivity is configurable and an 5 alarm level can be set. When used with compatible Aritech panels, contamination levels are monitored, drift compensation is applied and a contamination warning is provided.
Role in Fire Detection Systems
An addressable optical smoke detector provides early fire detection by sensing smoke, which develops before flames appear. As each detector has its own address, the exact location of a fire is displayed on the panel when an alarm occurs. The advanced protocol, which includes CRC error checking and multi-bus loop codes, provides reliable operation without compromising communication speed.
Why Choose It?
- Replaceable optical chamber: During maintenance, only the chamber needs to be replaced; no special equipment or device replacement pool is required.
- Easy addressing: A straightforward numerical address from 1 to 128 is set using two rotary switches; no binary or hexadecimal conversion is required.
- Remote self-test: The result of an internal test started from the fire panel is reported back to the panel.
- 360° visibility: Dual alarm LEDs are visible from every direction.
- Standard base: All 2000 series detectors fit the same base and can be replaced easily.
Installation and Commissioning
DP2061N is ceiling-mounted by fitting it to an 2000 series detector base and is powered by the loop. Set the detector address using the two rotary switches before installation. Once the base wiring is complete, fit the detector into the base and add it to the system using automatic device discovery at the fire panel. Plan the layout so that the coverage area is below 80 m², and ensure the design complies with EN54 and local regulations. During commissioning, it is recommended that you carry out a self-test from the fire panel and a smoke test.
Technical Specifications
- Status indication: Dual red alarm LEDs
- Alarm levels: 5
- Compatibility: Aritech 2000 systems
- Connection: 2000 series detector bases
- Addressing: Rotary switch (1-128)
- Power supply: Loop-powered, 17-28 VDC
- Current consumption: 350 µA (standby at 24 VDC) / 4 mA (alarm at 24 VDC)
- Detection principle: Optical light scattering
- Monitoring: Alarm threshold, contamination level
- Sensitivity: Configurable
- Coverage area: 60–80 m²
- Output: 1 remote indicator output, 4 mA, non-programmable
- Dimensions: 100 x 50 mm (Ø x H)
- Net weight: 115 g
- Colour / housing: Cloud white (RAL 9001) / plastic
- Mounting: Base-mounted
- Operating / storage temperature: -10 to +55°C / -10 to +70°C
- Relative humidity: 10–95%, non-condensing
- Protection rating: IP43, indoor use
- Compliance: CE, REACH, RoHS 2, WEEE / CPR
- Standard: EN54-7:2018, CPR certificate 1134-CPR-010; polarity-sensitive
Applications
- Offices and administrative buildings
- Hotel rooms and corridors
- Schools and halls of residence
- Hospital patient rooms and corridors
- Shopping centres and shops
- Archives, storage rooms and plant rooms
Compatible Products
DP2061N can be used with the Aritech 2000 series DB2002 standard base, DB2004 deep base, DB2016 isolator base and DB2368IAS-W isolator sounder base. An AI672 or buzzer-equipped AI673 can be connected as a remote indicator. The detector is compatible with Aritech 2X-AF1-19 and 2X-AF2-19 addressable fire alarm control panels.
Frequently Asked Questions
What should I do if the optical chamber becomes dirty? The chamber can be replaced on site; there is no need to replace the entire detector or send it to a workshop.
How is the address set? Set a numerical address from 1 to 128 directly using the two rotary switches on the detector.
Which bases can it be used with? It is compatible with all 2000 series bases; DB2002, DB2004 and isolator-equipped DB2016 are the most common options.
At Narstek, we provide technical support with the selection, project design and commissioning of Aritech 2000 series addressable detectors. Contact us for project support and a quote.
Other Aritech products

Aritech DP2061T Addressable Multisensor Detector (Optical-Heat)

Aritech DP721I Conventional Optical Smoke Detector

Aritech DP721R Conventional Optical Smoke Detector with Relay

Aritech DP721RTA Conventional Multisensor Detector with Relay Output
Request a site survey and quote for your project
Tell us about your building, existing system and requirements; together, we can determine the right solution.