Aritech DT2063N Addressable Heat Detector
Request a quote for pricing and availability. Installation, commissioning and compatibility checks with your existing system are also available.
Product description
1. Product Name: Aritech DT2063N Addressable Heat Detector
2. Description:
What Is the Aritech DT2063N Addressable Heat Detector?
The Aritech DT2063N is an addressable heat detector certified to Class A2R and operating with the 2000 series protocol. Its dual-thermistor design and rate-of-rise algorithm can trigger an alarm before the fixed temperature threshold is reached. It is approved to EN54-5 and CPR-certified.
Operating Principle
The detector’s dual thermistors continuously measure the ambient temperature. If the temperature rises rapidly, the rate-of-rise algorithm activates and triggers an alarm without waiting for the fixed alarm point to be reached; for slowly developing fires, the fixed temperature threshold applies. The fixed trigger level can be adjusted via the panel (CIE) for applications requiring a higher temperature threshold.
Role in Fire Detection Systems
Heat detectors are preferred in dusty, steamy or smoky environments where smoke detectors may generate false alarms. Thanks to its addressable design, the DT2063N reports its exact location to the panel when an alarm occurs. The SIA-based protocol, which includes CRC error checking and multi-data bus loop codes, provides reliable and fast communication between the panel and the device.
Why Choose It?
- A2R-class detection: The rate-of-rise algorithm enables early alarm activation.
- Adjustable threshold: The fixed trigger temperature can be raised via the panel.
- Easy addressing: A numerical address from 1 to 128 is set using two rotary switches.
- Visibility from all directions: Dual alarm LEDs mean no specific mounting orientation is required.
- Unaffected by airflow: Measurement is unaffected by the speed of the ambient air.
Installation and Commissioning
The DT2063N is ceiling-mounted by fitting it to a 2000 series base. The address is set using the two rotary switches on the detector; since the dual LEDs are visible from all directions, the detector does not need to be installed in a particular orientation. The layout should be planned so that the coverage area remains below 80 m². Once the detector has been added to the panel, the fixed trigger temperature can be adjusted if necessary, and operation verified with a heat test. An isolator base is available as an option.
Technical Specifications
- Status indication: Dual red alarm LEDs
- Alarm levels: 5
- User interface: LED
- Compatibility: Aritech 2000 series systems
- Connection: 2000 series bases
- Operating voltage: 17–28 VDC
- Current consumption: <270 µA (standby at 24 VDC) / 4,7 mA (alarm at 24 VDC)
- Detection principle: Heat (dual thermistor)
- Monitoring: Alarm threshold
- Sensitivity: Configurable
- Coverage area: 60–80 m²
- Air velocity: Unaffected
- Alarm temperature (typical): > +40°C
- Rate-of-rise class: Class A2
- Output: 1 remote indicator output, 4,7 mA, non-programmable
- Dimensions: 100 x 50 mm (Ø x H)
- Net weight: 83 g
- Colour / housing: Cloud white (RAL 9001) / plastic
- Mounting: Ceiling-mounted
- Operating / storage temperature: -10 to +50°C / -10 to +70°C
- Relative humidity: 10–95%, non-condensing
- Protection rating: IP20, indoor use
- Compliance: CE, REACH, RoHS 3, WEEE / CPR
- Standard: EN54-5:2017+A1:2018 (A2R), CPR certificate 0370-CPR-2410; polarity-sensitive
Applications
- Kitchens and canteens
- Car parks and loading areas
- Boiler rooms and plant rooms
- Dusty production areas
- Laundries and steamy environments
- Warehouses where smoke detectors are unsuitable
Compatible Products
The DT2063N can be used with Aritech 2000 series DB2002, DB2004, isolator-equipped DB2016 and sounder-equipped DB2368IAS-W bases. An AI672 or buzzer-equipped AI673 can be connected as a remote indicator. The detector is compatible with Aritech 2X-AF1-19 and 2X-AF2-19 addressable fire alarm control panels.
Frequently Asked Questions
What does A2R mean? In accordance with EN54-5, it indicates Class A2 temperature threshold detection combined with rate-of-rise (R) detection.
Can the alarm temperature be changed? Yes. The fixed trigger level can be adjusted via the panel for applications requiring a higher temperature.
Does the mounting orientation matter? No. The dual alarm LEDs are visible from all directions, so no specific mounting orientation is required.
At Narstek, we provide technical support with the selection, project design and commissioning of Aritech 2000 series addressable detectors. Contact us for project support and a quote.
Other Aritech products

Aritech DP2061N Addressable Optical Smoke Detector

Aritech DP2061T Addressable Multisensor Detector (Optical-Heat)

Aritech DP721I Conventional Optical Smoke Detector

Aritech DP721R Conventional Optical Smoke Detector with Relay
Request a site survey and quote for your project
Tell us about your building, existing system and requirements; together, we can determine the right solution.