Fire detection products
EN 54-compliant fire alarm control panels, detectors, manual call points, sounders and beacons, as well as contact and monitoring modules. A Turkish datasheet and wiring diagram are available for most products.

Apollo K67000M1 Repeater Panel

Apollo A81161M2 Addressable Fire Alarm Control Panel

Kentec Syncro AS 2 Addressable Fire Alarm Panel

Aritech 1X-F2-SC 2-Zone Conventional Fire Panel

Aritech 1X-F4 4-Zone Conventional Fire Alarm Panel

Aritech 1X-F4-SC 4-Zone Conventional Fire Panel

Aritech 1X-F8 8-Zone Conventional Fire Alarm Panel

Aritech 1X-X3E-09 3-Zone Conventional Fire Alarm and Suppression Panel

Aritech 2X-A-KIT-SA-1L Addressable Fire Alarm Panel, 1 Loop

Aritech 2X-A-KIT-SA-2L Addressable Fire Alarm Panel, 2 Loop

Aritech 2X-A-KIT-SA-2L-LB 2-Loop Addressable Fire Panel Set

Aritech 2X-A-LB Addressable Fire Panel 2-Loop Expansion Card

Aritech 2X-AE1 1-Loop Addressable Fire and Evacuation Panel

Aritech 2X-AE2 2-Loop Addressable Fire and Evacuation Panel

Aritech 2X-AER-C Compact Addressable Fire Alarm Repeater Panel

Aritech 2X-AF1-19 1-Loop Addressable Fire Alarm Panel (Turkish)

Aritech 2X-AF1-FB Single-Loop Addressable Fire Panel with Fire Brigade Controls

Aritech 2X-AF1-FB-S 1-Loop Addressable Fire Panel with Fire Brigade Controls

Aritech 2X-AF1-S 1-Loop Addressable Fire Alarm Panel, Small Cabinet

Aritech 2X-AF1-SCFB 1-Loop Addressable Fire Panel with Scandinavian Interface

Aritech 2X-AF1-SCFB-S Addressable Fire Panel with Scandinavian Interface

Aritech 2X-AF2-19 2-Loop Addressable Fire Alarm Panel (Turkish)

Aritech 2X-AF2-FB Two-Loop Addressable Fire Panel with Fire Brigade Controls

Aritech 2X-AF2-FB-P 2-Loop Addressable Fire Panel with Fire Brigade Controls

Aritech 2X-AF2-FB-P-W-99 2-Loop Addressable Fire Panel, Large Cabinet

Aritech 2X-AF2-FB-PRT Addressable Fire Panel with Printer

Aritech 2X-AF2-FB-PRT-P 2-Loop Addressable Fire Panel with Printer

Aritech 2X-AF2-FB-S 2-Loop Addressable Fire Panel with Fire Brigade Controls

Aritech 2X-AF2-FB-S-W-99 2-Loop Addressable Fire Panel, Small Cabinet

Aritech 2X-AF2-P 2-Loop Addressable Fire Alarm Panel with High-Power Supply

Aritech 2X-AF2-PRT 2-loop Addressable Fire Alarm Control Panel with Printer

Aritech 2X-AF2-PRT-P 2-loop Addressable Fire Alarm Control Panel with Printer

Aritech 2X-AF2-S 2-Loop Addressable Fire Alarm Panel, Small Cabinet

Aritech 2X-AF2-SCFB 2-Loop Addressable Fire Panel with Scandinavian Interface

Aritech 2X-AF2-SCFB-P 10 A-fed fire panel with Scandinavian interface

Aritech 2X-AF2-SCFB-S Addressable Fire Panel with Scandinavian Interface

Aritech 2X-AFR-19 Addressable Fire Alarm Repeater Panel (Turkish)

Aritech 2X-AFR-C Compact Addressable Fire Alarm Repeater Panel

Aritech 2X-AFR-FB Addressable Fire Alarm Repeater Panel with Fire Brigade Controls

Aritech 2X-AFR-FB-C Compact Fire Alarm Repeater Panel with Fire Brigade Controls

Aritech 2X-AFR-FB-S Addressable Fire Alarm Repeater Panel with Fire Brigade Controls

Aritech 2X-AFR-S Addressable Fire Alarm Repeater Panel in a Small Cabinet

Aritech 2X-AFR-SCFB-C Compact Addressable Fire Alarm Repeater Panel

Aritech 2X-F1 1-loop Addressable Fire Alarm Control Panel

Aritech FC2012 1200/2000 Series Main CPU Board

Aritech FP2864C-01 Addressable Fire Alarm Control Panel

Aritech FRG2064C-21 16-zone General Repeater, expandable to 64 zones

Aritech ZE2016 16-zone LED Expansion Board
No products found matching these criteria.
If the product you are looking for is not in our catalogue, contact us and we will source it for you.
Choosing the right products for fire detection systems
A fire detection system consists of a control panel, field devices and the circuits connecting them. In addressable systems, each device appears at the panel with its own address, allowing the precise location of a fire to be identified. In conventional systems, devices are grouped by zone, providing an economical solution for small and medium-sized buildings. Wireless systems are preferred in historic buildings where running cables is difficult and in businesses that cannot suspend operations.
At Narstek, we select compatible products, expand systems, carry out maintenance and repair faults in systems installed using different brands. Sharing your panel brand and model is enough for us to find the right detector and module.
About fire detection products
Should I choose an addressable or conventional system?
The choice depends on the size of the building, the number of sections and how precisely the location of a fire needs to be identified. Addressable systems are suitable for multi-storey buildings with many sections and for places such as hospitals, hotels and shopping centres; conventional systems are generally sufficient for small offices, warehouses and shops.
Can detectors from a different brand be connected to the existing panel?
In addressable systems, detectors and modules usually depend on the panel’s communication protocol, so products from the same brand or with a compatible protocol are required. Conventional systems offer broader compatibility, but line current and end-of-line values must be checked.
How often should a fire alarm system be maintained?
Under the Regulation on the Protection of Buildings from Fire and TS EN 54 / TS 54-14, systems must be tested periodically and maintenance must be recorded. The general practice is to carry out maintenance at least twice a year.
Can't find the product you're looking for?
We also provide sourcing support for models and spare parts not listed in our catalogue.
